4 Introduction
INX-420 System Diagram
Power Control Board - Behind the reservoir, the Power Control Board is
responsible for a number of tasks, including: powering the pumps, LED display,
heat exchanger fans, and operating the audio alarm and shutdown modes.
Reservoir & Pumps - The coolant tank includes many features which are
distinctive to a Koolance system. It is also translucent for easy liquid-level
monitoring. Dual pumps carry a flow rate of approximately 1030cc/min.
Redundancy also provides higher system reliability; if one pump should fail, the
other will maintain an acceptable temperature, or gradually bring the system to
shut itself down (see LED Display Panel).
Heat Exchanger - The heat exchanger, or radiator, is located beneath the fan
cooling module. This is the primary cooling element, specifically designed for
liquid cooling, and provides high thermal dissipation in a relatively small area.
Inside, an aluminum mesh (Louver fin) is webbed between 13 horizontal liquid
paths.
Power Control Board
Heat Exchanger
Power Switch
& Temp. Probe
Wires
Reservoir & Pumps
Liquid Inlet/Outlet Nozzles