Introduction
PC3-700 System Diagram
Reservoir & Pumps Radiator Cooling Fans
Reservoir Refi ll Tap
Radiator (Primary Heat Exchanger)
Power Circuit Board
Power Connection
ATX Power Switch &
Temperature Sensors
LED Display Panel
Inlet / Outlet Nozzles
Reservoir & Pumps - The coolant tank is translucent for easy liquid-level monitoring.
Dual pumps help to provide higher system reliability; if one pump should fail, the
other can maintain fl ow, gradually bringing the system to shut itself down (see
LED Display Panel).
Power Circuit Board - Beneath the reservoir, the Power Circuit is responsible for
a number of tasks, including: powering the pumps, LED display, heat exchanger
fans, and operating the audio alarm and shutdown modes.
Radiator - The primary heat exchanger is located beneath the fan cooling module.
This is the main cooling element, and provides high thermal dissipation in a
relatively small area. Inside, an aluminum mesh (Louver fi n) is webbed between
14 horizontal liquid paths.